This website or its third party tools use cookies, which are necessary to its functioning and required to achieve the purposes illustrated in the cookie policy. If you want to know more or withdraw your consent to all or some of the cookies, please refer to the cookie policy. By closing this banner, scrolling this page, clicking a link or continuing to browse otherwise, you agree to the use of cookies..

Universal interface CG2 (4 IN conf. as DI or NTC / 4 OUT) with thermostat function

Universal interface CG2 (4 IN conf. as DI or NTC / 4 OUT) with thermostat function
ORDERING CODE
EK-CG2-TP
DESCRIPTION
KNX bus device functioning as 4-channel input configurable for the connection of potential-free contacts or passive temperature sensors (NTC 10 kΩ at 25°C, to be ordered separately) and 4-channel output for control of low-consumption LED. Room thermostat function for 4 independent zones. Mounting in wall box or on 35 mm rail (EN 60715) with the support EK-SMG-35 (to be ordered separately). Power supply via bus. Bus terminal block included in the delivery. To be used in KNX installations for home and building automation.
FUNCTIONS / CHARACTERISTICS
INPUTS (CONFIGURED FOR FREE-POTENTIAL CONTACTS)
• ON/OFF switching of single loads or group of loads
• dimming of lighting devices
• operating of shutters and roller blinds
• detecting the state of signaling contacts (from safety devices, alarms, etc.)
• recalling and saving of scenes
• sending on the bus of values (temperature, brightness, etc.)
• switching to forced functioning (lock)
• counting of impulses and switching cycles

INPUTS (CONFIGURED FOR NTC 10 kΩ at 25 °C TEMPERATURE SENSORS)
• Measurement of room air mass temperature with possibility of sending the value ​​on the bus or using the value for regulation through integrated thermostat function

OUTPUTS
• controlling of low-consumption LED to be used as state feedback, orientation nightlights, etc.

THERMOSTAT FUNCTION
• 2 points (ON / OFF) or proportional (PWM or continuous) room temperature regulation
• Heating and cooling modes with switching via bus
• Operating modes: comfort, standby, economy and building protection with separate setpoints for heating and cooling
• Automatic switching of the operating mode depending on presence or opening windows
• Regulation with weighted average between two temperature values
CONFIGURATION AND COMMISSIONING
A detailed description of the parameters can be found in the application manual of the device. Configuration and commissioning require ETS4 or later versions. ETS application program: APEKCG2TP##.knxprod (## = release). Available languages: English, French, German, Italian